Printer Error Problem Troubleshooting Tip
504- Report Not Found You have selected a report that does not exist. The report file no longer exist, which means the Series software needs to be reinstalled.
513- Invalid Printer The printer dirver for the printer you specified is missing. From within Windows, reinstall the printer driver back into Windows, then print out a test page to make sure printer driver is working in Windows first.

Or the selected printer in Reports Setup is blank.
515- Error in Formula There is formula error in the replacement formula text. Review the formula Syntax and retry. Solution1- Make sure there is no apostrophe(*), brackets (]) or any other invalid characters in any of the fields when trying to run report.
Solution2- Make sure that the Crystal Report File is the correct version for that program.
Solution3- Verify if the user installed Office 2000, or Second Generation Windows 98. If so, replace the windows\system\p2sodbc.dll with version 7.0.0.149.
525- Unable to Load Report There is something wrong with the report you are trying to open. Try printing a different report, if no errors are present then the first report file needs to be replaced or Series software needs to be reinstalled.
Check to see if correct version of CRPE32.DLL.
526- No Default Printer You have not specified a default printer. Check Windows to make sure the printer is selected as the default printer.
545- Request Cancelled by User You have not specified a default printer. Make sure that within Series, the correct printer is selected. It is located in the Setup\Reports Printers.

Other Printer Errors Within Series I-II

Error Troubleshooting Tip
Table of Database Cannot Be Opened When Starting
  • Delete the Windows\Temp directory.
  • Always run Scandisk to check for any other problems on the harddrive before proceeding.
  • From within the Mitchell Repair Group folder, run (in this order) the Repair Database Utility, and then the Update Database Utility. When finished, reboot Windows and restart the Series Program.

User License Errors:

Error Troubleshooting Tip
Error 1: Can’t Open Usage File
  • Program has already been opened in Windows 95. Bring up "Close Program" and if Series is listed than tells that the program is already up and running.
  • Multi User- Server hard drive is not shared with full access.
Error 2 or -2: Can’t Open Usage File or You have tried to open two copies of your management program please close and double click the icon once.
  • Program has already been opened in Windows 95. Bring up the task bar (where Start button is located) and click on the MMS Series X program.
  • Multi User- Server hard drive is not shared with full access.
Error 3: Usage Over Limit
  • In a multi-user setup, the limit of user access has reached its limit. Make sure the number of computers accessing the software has not exceeded the limit.
Error 4: Can’t Open Access File
  • Workstation lost drive mapping to the server's hard drive.
  • Computer is low on resources.
  • Mitchell Parts & Labor Estimating Guide is not working correctly.
Error 6: Access CRC Bad
  • The directory does not have full shared access.
Error 7: Hidden Directory
  • The temp directory in the Series I-II program directory (usually C:\Mitchell\Repair\SeriesX\Temp) is not empty or present. Close program and delete files found there, or reinstall the program.
Error 10: Directory Timestamp
  • Verify the server and workstation are on the same date and time. If needed, rerun the workstation setup.
  • Series 32bit can call for an access code to reactivate.
Error 14: A License Error Occurred  
Error 20: Open Exclusively
  • Someone is running the database utilities.
Error 22: A License Error Occurred
  • User did not wait for "installation complete dialog" before starting Series.
Error 23:
  • File in Hidden Directory.
1 (4)
Article Rating (4 Votes)
Rate this article
  • Icon PDFExport to PDF
  • Icon MS-WordExport to MS Word
Attachments Attachments
There are no attachments for this article.
Comments Comments
Related Articles RSS Feed
Inventory Merge - Which Part Is Master
Viewed 1029 times since Wed, Jun 11, 2008
Your network configuration is using UNC which is not supported by Management Systems
Viewed 788 times since Thu, Jul 26, 2012
Mgmt: Slow Startup / Catalog Error Msg
Viewed 909 times since Mon, Jan 12, 2009
Shop Management: How to perform a refund
Viewed 4177 times since Tue, Dec 12, 2017
Fix To Open WorldPAC From Manager
Viewed 3641 times since Wed, Mar 10, 2010
Creating a Prior Balance For Customer
Viewed 1188 times since Wed, Aug 13, 2008
DIFFERENT PDF WRITERS FOR USE WITH MANAGER PROGRAMS
Viewed 946 times since Thu, Jul 26, 2012